how do I use 30 amp consumables and height control? I have a Plasma Cam table with PM45 cutter I also have advanced height control.
do I need to make a OHMIC sensor? change pierce height and cut height. I'm cutting art out of 14,12,10 ga steel
Thanks Bill
PM45 with 30 amp consumables hight control
-
- 1.5 Star Elite Contributing Member
- Posts: 49
- Joined: Sat Jul 20, 2013 12:42 am
- Contact:
PM45 with 30 amp consumables hight control
4X4 Plasma Cam DHC2
w/down draft Hypertherm 45
3x4x6 home made powder coating oven
w/down draft Hypertherm 45
3x4x6 home made powder coating oven
-
- 4 Star Elite Contributing Member
- Posts: 2033
- Joined: Fri Apr 17, 2009 11:48 am
Re: PM45 with 30 amp consumables hight control
Using 30 amp consumables should be no different than using your 45 amp consumables with the exception of determining the correct arc voltage to achieve the proper cutting height. For the thicker sheets your cutting I think your best to stick with your 45 amp consumables.
-
- 5 Star Elite Contributing Member
- Posts: 3087
- Joined: Mon Jul 20, 2009 11:18 pm
- Location: North Carolina
Re: PM45 with 30 amp consumables hight control
You can make an ohmic sensor that will work with the 30 amp unshielded consumables. Use a stiff piece of copper wire that extends about .010" lower than the nozzle, hose clamp it to the plastic part of the retaining cap and put a spade style wire connector on the upper end of the wire. Connect the plasmacam ohmic connect wire to the spade connector.
Jim Colt Hypertherm
Jim Colt Hypertherm
-
- 1.5 Star Elite Contributing Member
- Posts: 49
- Joined: Sat Jul 20, 2013 12:42 am
- Contact:
Re: PM45 with 30 amp consumables hight control
thanks I plan to use 45 amp on 12 and 10ga 30amp on 14weldguy wrote:Using 30 amp consumables should be no different than using your 45 amp consumables with the exception of determining the correct arc voltage to achieve the proper cutting height. For the thicker sheets your cutting I think your best to stick with your 45 amp consumables.
4X4 Plasma Cam DHC2
w/down draft Hypertherm 45
3x4x6 home made powder coating oven
w/down draft Hypertherm 45
3x4x6 home made powder coating oven
-
- 1.5 Star Elite Contributing Member
- Posts: 49
- Joined: Sat Jul 20, 2013 12:42 am
- Contact:
Re: PM45 with 30 amp consumables hight control
Thank you Jim I will give it a try.jimcolt wrote:You can make an ohmic sensor that will work with the 30 amp unshielded consumables. Use a stiff piece of copper wire that extends about .010" lower than the nozzle, hose clamp it to the plastic part of the retaining cap and put a spade style wire connector on the upper end of the wire. Connect the plasmacam ohmic connect wire to the spade connector.
Jim Colt Hypertherm
4X4 Plasma Cam DHC2
w/down draft Hypertherm 45
3x4x6 home made powder coating oven
w/down draft Hypertherm 45