hypertherm 85a on piranha plasma cutter

For general topics and questions that do not fit into any of the other categories or forums.
Post Reply
Chris_m42
1/2 Star Member
1/2 Star Member
Posts: 2
Joined: Thu Jun 01, 2023 10:23 am

hypertherm 85a on piranha plasma cutter

Post by Chris_m42 »

i keep getting a 0-30-0 error code on my plasma cutter. I have replaced and cleaned the swirl ring, and all consumables. checked my airlines for any moisture and found none. raised the initial and cutting height to see if that changes anything and it does not. I can sometimes cut four parts and others cut one hole. if anyone knows anything else please reply.
plasmanewbie
5 Star Elite Contributing Member
5 Star Elite Contributing Member
Posts: 2607
Joined: Thu Jul 24, 2008 11:15 am

Re: hypertherm 85a on piranha plasma cutter

Post by plasmanewbie »

There is an entire section on fault codes here https://www.plasmaspider.com/viewforum.php?f=207 that I think not many people know about. Check it out and it may be of help.
Post Reply

Return to “CNC Plasma Cutters General Forum”