I have a Miller 625 SN MF063116P (I have the owners manual) that I’m trying to trouble shoot before I take it to a dealer. It’s my utility cutter that I use for general off table cutting. I use a hypertherm 85 for table cutting which has never skipped a beat.

When powered up the fan comes on, turns off, on again faster, off, on again faster and the power light flashes. I also get the three pulses on the cup icon indicating possible stuck consumables. Below is what I’ve done.

Confirm voltage to unit is 240V
Installed all new consumables
Cup micro switch has continuity when depressed
Trigger micro switch not stuck, closed circuit when depressed.
Air supply is 120 psi. I use a refrigerated air dryer, filter before the unit and opened the case to make sure the internal filter was perfectly clean
Blew inside of unit clean with compressed air although it was not very dirty
No evidence of black marks on circuit board or blown capacitors
Disassembled power cord and no evidence of shorts, corrosion or bad connections
Disassembled torch head and no pinched wires or obvious wiring issues.

I’d like to see the service manual if anyone has access to one or if there is something else I can check.

weldguy
Elite Contributing Member
Elite Contributing Member
Posts: 868
Joined: Fri Apr 17, 2009 11:48 am

Re: Miller Spectrum 625 X-treme Troubleshooting/Anyone have a service manual to share?

Post by weldguy » Mon Nov 15, 2021 11:27 am

Sounds like you've done all your homework and all the tests. Searched high and low for a service manual I thought I had from years ago but no luck. Hope your able to get it resolved.

TXTig
Posts: 36
Joined: Mon Nov 09, 2020 3:33 am

Re: Miller Spectrum 625 X-treme Troubleshooting/Anyone have a service manual to share?

Post by TXTig » Fri Nov 19, 2021 9:17 pm

I gave up and took it to the LWS where I bought it and they are going to send it in for evaluation. I think that if it is the board I'll just take it back home and buy another Hypertherm. The hypertherm I use on the table has worked flawlessly for nearly 3 years; sometimes cutting up to 8 hours/day. Just used the Miller to trim pieces and cut pipe saddles.