Losing arc voltage and plasma cutting off
-
- 2.5 Star Member
- Posts: 218
- Joined: Sat Mar 12, 2011 11:26 pm
Losing arc voltage and plasma cutting off
Just got my new samson 510 up and going. I am running a PM85 with a machine torch. I have it attached with a new snap n cut and when I run fine cut consumables I am losing arc voltage and shutting off. I had a DHC2 with a PM65 before this setup so I have a good idea on how to run it. I have checked the air pressure, new consumables, checked wiring and adjusted setting to its lowest voltage reading for cutting signal. What am I doing wrong? I cun run the regular 45amp consumables with no issue. Anybody have the solution? Thanks Justin
Samson 510
Hypertherm PM85
Hypertherm PM85
- SeanP
- 4 Star Member
- Posts: 950
- Joined: Thu Aug 01, 2013 11:50 am
- Location: Co Kerry, Ireland
Re: Losing arc voltage and plasma cutting off
Are you sure your pc is up to scratch?
I was having intermittent problems losing arc part way through a cut ever since I built the machine, 12 months on I got a cheap dell optiplex 745 small form (not the ultra small) off ebay for 45 euro delivered, cured my problem completely.
Even bought another for a spare.
I was having intermittent problems losing arc part way through a cut ever since I built the machine, 12 months on I got a cheap dell optiplex 745 small form (not the ultra small) off ebay for 45 euro delivered, cured my problem completely.
Even bought another for a spare.
Powermax XP45
Home built table, Candcnc DTHC 2, Dragoncut 620-4
R-Tech 210 Tig, Jasic 250 mig
Sheetcam, Scanything, Coreldraw
Table build gallery
Home built table, Candcnc DTHC 2, Dragoncut 620-4
R-Tech 210 Tig, Jasic 250 mig
Sheetcam, Scanything, Coreldraw
Table build gallery
-
- 2.5 Star Member
- Posts: 218
- Joined: Sat Mar 12, 2011 11:26 pm
Re: Losing arc voltage and plasma cutting off
It ran my 4x4 with no issues. Same software just larger table.
Samson 510
Hypertherm PM85
Hypertherm PM85
-
- 5 Star Elite Contributing Member
- Posts: 3087
- Joined: Mon Jul 20, 2009 11:18 pm
- Location: North Carolina
Re: Losing arc voltage and plasma cutting off
After it shuts off.....there will be an error code on the digital readout on the Powermax85. Let me know what that is and I can likely help. The Finecut parts are more touch in regards to having the correct pierce height, pierce delay and cut height. Also, make sure inlet air pressure never goes below 90 psi or above 135 psi.....you would need a gauge installed right at the inlet to measure this, and it needs to be read only while air id flowing at the torch. Make sure your cut air pressure is set in auto mode.
Make sure you are using the ohmic contact and auto calibrate the z axis to ensure pierce/cut heights are correct.
Jim Colt Hypertherm
Make sure you are using the ohmic contact and auto calibrate the z axis to ensure pierce/cut heights are correct.
Jim Colt Hypertherm
SomethingMetal wrote:Just got my new samson 510 up and going. I am running a PM85 with a machine torch. I have it attached with a new snap n cut and when I run fine cut consumables I am losing arc voltage and shutting off. I had a DHC2 with a PM65 before this setup so I have a good idea on how to run it. I have checked the air pressure, new consumables, checked wiring and adjusted setting to its lowest voltage reading for cutting signal. What am I doing wrong? I cun run the regular 45amp consumables with no issue. Anybody have the solution? Thanks Justin
-
- 2.5 Star Member
- Posts: 218
- Joined: Sat Mar 12, 2011 11:26 pm
Re: Losing arc voltage and plasma cutting off
Jim I have an air pressure regulator 3 foot before going into the plasma cutter. The other weird thing is that the plasma cutter isn't giving me an error code on the screen. I did read a post you had posted on here I believe about the normal operating air pressures. I have checked mine and I am holding a solid 110psi supply to the cutter. I tried several different test cuts using the same same and it would almost always cut out at the same location on every cut. So I thought maybe it was something with my cut path. Tried a couple more with the same issues. Any other suggestions? I guess I can try new consumables but these were new before the test cuts.
Samson 510
Hypertherm PM85
Hypertherm PM85
-
- 1 Star Member
- Posts: 17
- Joined: Mon Feb 20, 2017 9:26 am
Re: Losing arc voltage and plasma cutting off
Bring up this old thread, because having the exact same problem. Did you ever find the problem? My problem is mainly on 10g and thinner.SomethingMetal wrote:Jim I have an air pressure regulator 3 foot before going into the plasma cutter. The other weird thing is that the plasma cutter isn't giving me an error code on the screen. I did read a post you had posted on here I believe about the normal operating air pressures. I have checked mine and I am holding a solid 110psi supply to the cutter. I tried several different test cuts using the same same and it would almost always cut out at the same location on every cut. So I thought maybe it was something with my cut path. Tried a couple more with the same issues. Any other suggestions? I guess I can try new consumables but these were new before the test cuts.
-
- 2.5 Star Member
- Posts: 112
- Joined: Mon Nov 10, 2014 10:55 am
Re: Losing arc voltage and plasma cutting off
Moisture in the air lines can also cause an error like this and other problems as well. Moisture in your airlines can be a big problem and Solving this will make a world of difference.
I would give Plasmacam tech support a call. They will certainly be a big help and save you some time. They have been very helpful in getting me up and going quickly. Plasmacams owners community has also been a great resource for information on things like this, especially after hours.
Good Luck,
JAG
I would give Plasmacam tech support a call. They will certainly be a big help and save you some time. They have been very helpful in getting me up and going quickly. Plasmacams owners community has also been a great resource for information on things like this, especially after hours.
Good Luck,
JAG