Post by dava »

The company I work for has an alltra plasma cutter, we are having an issue where our consumables have gone from a life of about 1000 pierces to a life of 500 pierces. The operator is saying at the end of the 500 pierces, the spark will not fire by the nozzle. He also said the coolant/pink fluid usage has gone up significantly, could we possibly have a coolant leak?
Heliarcman
1/2 Star Member
1/2 Star Member
Posts: 1
Joined: Tue Feb 20, 2018 1:05 am

Re: Tech support needed

Post by Heliarcman »

What kind of plasma system are you using Make & model? (Hypertherm/Thermal Dynamics??)

The coolant for the torch is a closed loop system, so if you have to refill often, then you have a leak.
dava
1 Star Member
1 Star Member
Posts: 13
Joined: Thu Apr 22, 2010 4:59 pm

Re: Tech support needed

Post by dava »

it is an alltra plasma table with a hypertherm hpr400xd.
weldguy
4 Star Elite Contributing Member
4 Star Elite Contributing Member
Posts: 1951
Joined: Fri Apr 17, 2009 11:48 am

Re: Tech support needed

Post by weldguy »

Sounds like a coolant leak to me and if it is getting into the air stream the moisture will dramatically reduce your consumable life. Check and replace all orings/seals for sure.
jimcolt
5 Star Elite Contributing Member
5 Star Elite Contributing Member
Posts: 3087
Joined: Mon Jul 20, 2009 11:18 pm
Location: North Carolina

Re: Tech support needed - HPR 400XD

Post by jimcolt »

First line for tech support is to contact ALLtra in Oklahoma, if further help is needed contact Hypertherm technical service. technical.service@hypertherm.com or 1 800 643 9878 Jim Colt Hypertherm